2-4 Site preparation
553-4001-111 Standard 1.0 March 1997
Environmental requirements
Ensure that your site can maintain the required environmental conditions
for the Meridian MAX hardware before beginning the installation.
Note: At all times, the front and back panels of the Application
Equipment Module (AEM) and the Meridian 1 should be closed and
latched. This ensures that the temperature within the Meridian column
remains reasonably constant and within the operating temperatures of
the equipment.
Meridian MAX Application Module
The following list details the environmental requirements for your Meridian
MAX hardware:
• operating temperature between 10°C–35°C (50°F–104°F)
• non-operating temperature between –10°C–60°C (14°F–140°F)
• changes in temperature less than 20°C/hour (68°F/hour)
• operating humidity between 20%–80% (noncondensing)
• nonoperating humidity between 20%–80% (noncondensing)
• operating altitude between 0–3.24 km (0–10 000 ft)
Meridian MAX IPE/IPE-E module
The environmental requirements for the Meridian MAX IPE/IPE-E
hardware are
• operating temperature between 10°C–35°C (50°F–95°F)
• non
-operating temperature between –20°C–70°C (–4°F–158°F)
• changes in temperature less than 20°C/hour (68°F/hour)
• operating humidity between 20%–80% (noncondensing)
• nonoperating humidity between 20%–90% (noncondensing)
• operating altitude between 0–3.24 km (0–10 000 ft)
• nonoperating altitude between 0–9.14 km (0–30 000 ft)
To use the HP LaserJet II printer, the environmental range must be between
10°C–32.5°C (50°F–90.5°F) with a maximum altitude of 2.6 km (8200 ft).