8-4 Meridian 1 circuit card configuration
553-4001-111 Standard 1.0 March 1997
The QPC841 Serial Data Interface (SDI) operates as a DTE device. Set the
QPC841 DTE/DCE mode selection to DCE mode (modem).
• Port 1 SW8 is set all to OFF.
• Port 1 SW9 is set all to ON.
• Port 2 SW6 is set all to OFF.
• Port 2 SW7 is set all to ON.
• Port 3 SW4 is set all to OFF.
• Port 3 SW5 is set all to ON.
• Port 4 SW2 is set all to OFF.
• Port 4 SW3 is set all to ON.
The High-Speed Link (HSL) cable or Load Management Link (LML) cable
used with the QPC841 SDI and the QPC139 SDI link is referred to as part
number NT1R03Dx, where x can be B, C, F, P, or V depending on the
length of the cable. This cable connects the Meridian MAX to the Meridian
1 and can be used as the High-Speed Link or Load Management Link.
Note: The Configuration Control feature uses a Load Management
Link that is also referred to as a Configuration Control Link.
The NT8D41 Serial Data Interface (XSDI) operates as a DTE device. Set
the NT8D41 DTE/DCE mode selection to DCE mode (modem).
• Port 1 SW5 is set all to OFF.
• Port 1 SW6: dipswitches 1, 3-6 are set to ON; dipswitch 2 is set to
OFF.
• Port 2 SW7 is set all to OFF.
• Port 2 SW8: dipswitches 1, 3-6 are set to ON; dipswitch 2 is set to
OFF.
The High-Speed Link (HSL) cable or Load Management Link (LML) cable
used with the NT8D41 SDI is referred to as part number NT8D93Ax,
where x can be J or W, depending on the length of the cable. This cable
connects the Meridian MAX IPE/IPE-E to the Meridian 1 and can be used
as the High-Speed Link or Load Management Link.