Meridian 1 circuit card configuration 8-5
Meridian MAX
Installation Guide
Product release 8
Configuring the Meridian 1 NT6D80 MSDL card for use
with the High-Speed Link or the Load Management Link
To configure the Multi-purpose Serial Data Link card (MSDL) for use with
the High-Speed Link (HSL) or the Load Management Link (LML) on the
Meridian 1, follow the steps in Procedure 8-1.
Before configuring your MSDL card on the Meridian 1 for use with the
HSL or LML, contact your Meridian 1 administrator to ensure the
following criteria is met:
• Switch settings on the MSDL card must be correct for HSL and LML
configuration.
• Port 0 on the MSDL card is an asynchronous port. It must be available
for the configuration of the HSL or the LML. The HSL and LML must
be configured on separate MSDL cards.
Procedure 8-1
To configure the Meridian 1 NT6D80 MSDL card for use with the
High-Speed Link or the Load Management Link
1 If there are no MSDL cards installed on your current system, refer to
the
Circuit Card Installation and Testing Guide
(NTP 553-3001-211) for
information on installing MSDL circuit cards, and continue with this
procedure.
If MSDL cards are already installed on your current system, go to Step
11.
2 Configure the MSDL card using the Meridian 1 maintenance terminal.
Use the document
X11 System Management Applications Guide
(NTP 553-3001-301) and the following guidelines. For prompts not
listed, press {ENTER} to select the default value.
Note:
Ensure “Caps Lock” on your keyboard is set to “on”.
Enter LD 22 to access Overlay program 22 to verify that MSDL (222)
and MSDL SDI (227) software is loaded on your system.
The system displays the following prompt:
REQ
3 Enter PRT to access the program’s print function.
The system displays the following prompt:
TYPE