Software installation overview 10-11
Meridian MAX
Installation Guide
Product release 8
Figure 10-3
Inserting a cassette into the 155 Mbyte tape drive of a Meridian MAX IPE
tape
drive
Lock the tape latch
after the tape is inserted
Tape drive latch
Protected
Write enabled
Write
protect
tab
Open
tape
drive
Closed
LED
light
Arrow
points in
Notch points down
155 Mbyte installation/
backup tape (top view)
Cleaning the tape drive
The tape drive should be replaced when you receive repeated errors when
attempting to write to tape. You should also consider replacing the tape
drive if the light on the front of the tape drive is out, or if you cannot hear
or see the tape spinning.
The tape cartridge cavity should be cleaned after an initial pass with a new
tape cartridge or whenever dust or debris is visible inside the cartridge
cavity. It should also be cleaned after about 100 hours of operation or every
three to six months depending on utilization.
To clean the tape drive, you must use the cleaning kit (Number TZ-380)
provided through Teac America Inc. This kit can be obtained by contacting
your Nortel distributor.